R-410AAFFINITY™ SERIES DNX024-048 2-4 Ton279550-YIM-E-0610TABLE OF CONTENTSGeneral . . . . . . . . . . . . . . . . . . . . . . . . .
279550-YIM-E-061010 Johnson Controls Unitary ProductsCondensate DrainA condensate trap is recommended to be installed in the condensate drain. The plu
279550-YIM-E-0610Johnson Controls Unitary Products 11Figure 7: Typical Field Control Wiring Diagram Single Stage Thermostat - Single Stage Gas HeatFig
279550-YIM-E-061012 Johnson Controls Unitary ProductsFigure 9: Typical Field Control Wiring Diagram Two Stage Thermostat - Single Stage Gas HeatFigure
279550-YIM-E-0610Johnson Controls Unitary Products 13Figure 11: Typical Field Power Wiring DiagramTable 6: Electrical Data Size(Tons)VoltCompressors(e
279550-YIM-E-061014 Johnson Controls Unitary ProductsDNX024-048 Single Stage Gas Heat ComponentModelsDNX024 DNX036 DNX048Nominal Tonnage 2.0 3.0 4.0A
279550-YIM-E-0610Johnson Controls Unitary Products 15DNX024-048 Two Stage Gas Heat ComponentModelsDNX024 DNX036 DNX048Nominal Tonnage 2.0 3.0 4.0ARI
279550-YIM-E-061016 Johnson Controls Unitary ProductsCompressorsThe scroll compressor used in this product is specifically designed to operate with R-
279550-YIM-E-0610Johnson Controls Unitary Products 174. All piping should be cleaned of dirt and scale by hammering on the outside of the pipe and blo
279550-YIM-E-061018 Johnson Controls Unitary ProductsTable 9: Natural Gas Application Data-Single StageAvailable On ModelsInput(MBH)11. Heating capaci
279550-YIM-E-0610Johnson Controls Unitary Products 19Airflow PerformanceTable 13: Side Duct Application Size(Tons)ModeThermostatInputSpeedTapCFMExter
279550-YIM-E-06102 Johnson Controls Unitary ProductsDue to system pressure, moving parts, and electrical components, installation and servicing of air
279550-YIM-E-061020 Johnson Controls Unitary Products048(4.0)HeatN065W1 HEAT-A 1200 330 373 416 461 507 554 - - -W1 HEAT-B 1300 394 439 484 531 579 62
279550-YIM-E-0610Johnson Controls Unitary Products 21036(3.0)CoolLowY1 COOL-A 900 198 233 272 313 358 406 458 512 569Y1 COOL-B 760 166 190 222 262 310
279550-YIM-E-061022 Johnson Controls Unitary ProductsBlower Speed SelectionThe variable speed blowers are designed to deliver constant CFM regardless
279550-YIM-E-0610Johnson Controls Unitary Products 23The “Heat” Jumper on the CFM selection board should be set to “A” from the factory.Fan Only CFM:W
279550-YIM-E-061024 Johnson Controls Unitary ProductsMain Burner OperationHigh Heat Warm-upTwo stage models run high heat for the first 60 seconds fol
279550-YIM-E-0610Johnson Controls Unitary Products 25de-energizes the induced draft motor (if flame is not present) to attempt to open the pressure sw
279550-YIM-E-061026 Johnson Controls Unitary ProductsCirculating FanWhen the thermostat calls for FAN, the thermostat terminal G is energized signalin
279550-YIM-E-0610Johnson Controls Unitary Products 27Figure 16: Two Stage Gas Valve FrontFigure 17: Single Stage Gas Valve RearFigure 18: Two Stage Ga
279550-YIM-E-061028 Johnson Controls Unitary ProductsAdjustment of Temperature RiseAfter about 20 minutes of high heat operation, determine the furnac
279550-YIM-E-0610Johnson Controls Unitary Products 29Typical Wiring DiagramsTypical DNX024 Cooling Unit with Single Stage Gas Heat 208/230-1-60 volt W
279550-YIM-E-0610Johnson Controls Unitary Products 33. For installation on combustible material and may be installed directly on combustible flooring
279550-YIM-E-061030 Johnson Controls Unitary ProductsTypical DNX024 Cooling Unit with Two Stage Gas Heat 208/230-1-60 volt Wiring Diagram
279550-YIM-E-0610Johnson Controls Unitary Products 31Typical DNX036-048 Cooling Unit with Single Stage Gas Heat 208/230-1-60 volt Wiring Diagram
279550-YIM-E-061032 Johnson Controls Unitary ProductsTypical DNX036-048 Cooling Unit with Two Stage Gas Heat 208/230-1-60 volt Wiring Diagram
279550-YIM-E-0610Johnson Controls Unitary Products 33Typical DNX036-048 Cooling Unit with Single Stage Gas Heat 208/230-3-60 volt Wiring Diagram
279550-YIM-E-061034 Johnson Controls Unitary ProductsTypical DNX036-048 Cooling Unit with Two Stage Gas Heat 208/230-3-60 volt Wiring Diagram
279550-YIM-E-0610Johnson Controls Unitary Products 35Typical DNX036-048 Cooling Unit with Single Stage Gas Heat 460-3-60 volt Wiring Diagram
279550-YIM-E-061036 Johnson Controls Unitary ProductsTypical DNX036-048 Cooling Unit with Two Stage Gas Heat 460-3-60 volt Wiring Diagram
Subject to change without notice. Printed in U.S.A. 279550-YIM-E-0610Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 27955
279550-YIM-E-06104 Johnson Controls Unitary ProductsIn Canada:1. Canadian Electrical Code, CSA C22.12. Installation Codes, CSA - B149.1.3. Local plumb
279550-YIM-E-0610Johnson Controls Unitary Products 5LocationUse the following guidelines to select a suitable location for these units:1. Unit is desi
279550-YIM-E-06106 Johnson Controls Unitary ProductsFigure 2: Unit 4 Point Load WeightXCENTER OF GRAVITY49-1/8FRONTOF UNITY47-1/4"D""C&
279550-YIM-E-0610Johnson Controls Unitary Products 7Figure 3: Unit DimensionsA B VENT AIR OUTLET HOOD BLOWER SERVICE ACCESS COMPARTMENT PANEL GAS SUPP
279550-YIM-E-06108 Johnson Controls Unitary ProductsFigure 4: Dimensions Front and BottomFigure 5: Dimensions Back and Bottom6 19-1/4 11-7/8 8-7/8 FRO
279550-YIM-E-0610Johnson Controls Unitary Products 9Figure 6: Roof Curb1DuctworkThese units are adaptable to downflow use as well as rear supply and r
Comentarios a estos manuales